METRONMENA

Thermal Flow Switch

Thermal Flow Switch
نظرة عامة

A no-moving-parts switch for flow, level, interface and temperature alarms on liquids, gases and slurries. Insertion lengths 1.2" to 18", threaded, flanged, Tri-Clamp or retractable, to 241 bar and 454 °C, with SPDT/DPDT, relay or analogue outputs and Ex enclosures.

Insertion length1.2"–18"
Connection typethreaded / flanged / sanitary Tri-Clamp / retractable packing gland
Measuring rangeliquids: 0.01–5 ft/s; gases: 0.25–120 Nft³/s; additional model-dependent ranges up to 20,000 cc/s
Process pressureup to 241 bar
المواصفات الفنية

Thermal Flow Switch

Insertion length1.2"–18"
Connection typethreaded / flanged / sanitary Tri-Clamp / retractable packing gland
Measuring rangeliquids: 0.01–5 ft/s; gases: 0.25–120 Nft³/s; additional model-dependent ranges up to 20,000 cc/s
Process pressureup to 241 bar
Process temperature−100 to +454 °C
Wetted parts material316L stainless steel / Hastelloy C / Monel 400 / titanium; sanitary polished finish down to 20 Ra
OutputSPDT / DPDT / relay / analogue output
Accessoriesexplosion-proof enclosures, dual-port housings, calibration mode, fail-safe logic
Applicationflow, level, interface, and temperature alarms for liquids, gases, and slurries
Industryoil and gas, chemical, power generation including nuclear, food and pharmaceutical, mining, water treatment
التفاصيل

A thermal flow switch uses the same principle as a thermal mass flowmeter, reduced to a switch. Two sensors sit in the process; one is heated, and the temperature difference between them depends on how fast the medium carries heat away. Flow, or the presence of liquid at the probe, changes that difference and trips the output. With no moving parts, the switch is immune to fouling, wear and vibration and works equally on liquids, gases and slurries.

Insertion lengths range from 1.2" to 18" with threaded, flanged, sanitary Tri-Clamp or retractable packing-gland mounting. Ranges cover liquids from 0.01 to 5 ft/s and gases from 0.25 to 120 Nft³/s, with additional model-dependent ranges to 20,000 cc/s for very low gas flows. Process limits are 241 bar and −100 to +454 °C. Wetted parts are 316L stainless steel, Hastelloy C, Monel 400 or titanium, with a sanitary finish down to 20 Ra for food and pharmaceutical service.

Outputs are SPDT or DPDT relays or an analogue signal; options include explosion-proof enclosures, dual-port housings, a calibration mode and fail-safe logic.

The same probe serves as a flow switch in pipes, a level or interface switch in vessels, and a temperature alarm. Users include oil and gas, chemical, power generation including nuclear, food and pharmaceutical, mining and water treatment, often for pump protection, seal-flush monitoring and dry-run prevention.

حدد المواصفات مع مهندسينا

أرسل لنا ظروف عمليتك وسنوصي بالتكوين المناسب — مع عرض سعر خلال يوم عمل واحد.

اطلب عرض سعر