METRONMENA

Metal-Tube Variable Area Flowmeter

Metal-Tube Variable Area Flowmeter
نظرة عامة

A mechanical rotameter in an all-metal tube for pressures to 100 bar and temperatures to 400 °C, reading through a magnetic coupling. Sizes ½" to 4", 1 to 100,000 L/h, in 316L, Hastelloy, Monel, Inconel, Incoloy or titanium, with switches and 4–20 mA HART output.

Size½"–4"
Connection typeflanged / threaded / DIN hygienic / Tri-Clamp
Measuring range1–100,000 L/h
Process pressureup to 100 bar
المواصفات الفنية

Metal-Tube Variable Area Flowmeter

Size½"–4"
Connection typeflanged / threaded / DIN hygienic / Tri-Clamp
Measuring range1–100,000 L/h
Process pressureup to 100 bar
Process temperature−196 to +400 °C; higher temperatures available on request
Wetted parts material316 / 316L stainless steel / Hastelloy / Monel 400 / Inconel 600 / Incoloy 825 / super-austenitic stainless steel / titanium
Outputmechanical indication; optional 4–20 mA / HART® / fieldbus / PROFIBUS transmitter
Accessoriesswitches, inlet and outlet valves, self-regulator, dampener, insulation, heat tracing, panels, coatings
Applicationflow measurement of liquids and gases, including viscous and corrosive fluids
Industryoil and gas, chemical, petrochemical, power generation, water treatment
التفاصيل

A variable area flowmeter, or rotameter, is a tapered tube with a float inside. Flow lifts the float until the annular gap around it passes the flow at equilibrium, and the float position indicates the rate. It needs no power and no straight pipe runs, and it shows the flow directly on a local scale. The metal-tube version replaces the glass with a stainless steel tube and transmits the float position to the indicator through a magnetic coupling, so the meter can be used at high pressure and temperature and on opaque, corrosive or hazardous fluids.

Meters are available from ½" to 4" with flanged, threaded, DIN hygienic or Tri-Clamp connections, for flows from 1 to 100,000 L/h, pressures to 100 bar and temperatures from −196 to +400 °C or higher on request. Wetted parts are 316 / 316L stainless steel, Hastelloy, Monel 400, Inconel 600, Incoloy 825, super-austenitic stainless steel or titanium.

The standard output is the mechanical pointer; an electrical transmitter adds 4–20 mA, HART, fieldbus or PROFIBUS, and inductive switches give minimum and maximum flow alarms. Options include inlet and outlet valves, a self-regulator for constant flow, a dampener for pulsating flow, insulation and heat tracing, panel mounting and coatings.

Metal-tube rotameters are used for viscous and corrosive liquids and gases in oil and gas, chemical, petrochemical, power and water treatment, particularly for seal, purge and cooling flows and chemical dosing where a visible local reading matters.

حدد المواصفات مع مهندسينا

أرسل لنا ظروف عمليتك وسنوصي بالتكوين المناسب — مع عرض سعر خلال يوم عمل واحد.

اطلب عرض سعر